| INSULATION |
-
This property varies with the unit of weight of the concrete
which is dependent on the volume of pumice in the mix. The thermal
conductivity factor for normal weight concrete (145 p.c.f.)
is 12 as compared to 3.5 for concrete with a density of 100
p.c.f. and 1.9 for 60 p.c.f. |
| PERMEABILITY |
-
Despite the porous nature of the aggregate, concrete batched
with "AGG-LITE" has absorption characteristics very
similar to normal weight concrete. "VAC-LITE" saturated
pumice aggregate has nearly 90% external saturation and is used
mostly for pumping into place or to eliminate concrete slump
variations from batch to job site. |
|
|
AGGREGATE PROPERTIES
- Sieve analysis (1/2" x No. 4 structural
concrete)
|
SIZE
|
% PASSING
|
SPECIFICATION
|
|
1/2
|
100
|
90-100
|
|
3/8
|
60-70
|
40-80
|
|
No. 4
|
5-12
|
0-20
|
- Specific Gravity ............................................................................................
0.84-0.87
- Dry, loose unit weight ..................................................................................25-28
p.c.f.
- One hour absorption ...............................................................................18-22
percent
- Vacuum saturation ..................................................................................82-87
percent
Chemical Analysis
| SILICON DIOXIDE (SiO2) |
60.30%
|
| ALUMINUM OXIDE (Al2O3) |
16.26%
|
| IRON OXIDE (Fe2O3) |
2.80%
|
| MAGNESIUM OXIDE (MgO) |
5.74%
|
| SULPHUR TRIOXIDE (SO3) |
TRACE
|
| LOSS ON IGNITION |
4.69%
|
| MOISTURE CONTENT |
2.15%
|
| AVAILABLE ALKALIES |
0.96%
|
|
California
Lightweight Pumice, Inc., San Clemente, CA 92672
|